This solar water pump is constructed with an aluminum pump housing, iron pump head and powerful motor. It can be used to boost the water flow by 5.28/7.66 GPM. There are three speed circulating switches, which allow you to regulate the pressure and the maximum height can reach 13/16/20 ft with 3-speed circulating switch. It’s a reliable equipment that keeps quiet to work, so it won’t disturb you at night or early in the morning.
Get more out of your pool with our powerful solar water pump. Constructed from durable materials and designed for optimal performance, this pump will help circulate your pool water for a clean, clear pool. Whether you want to keep the water moving for evaporation or filtration, it will boost the flow of your current system.
50Hz | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Model | Model | Power P2(KW) | Q (m3/h) |
0.4 | 0.6 | 0.8 | 1.0 | 1.2 | 1.4 | 1.6 | 1.8 | 2.0 | 2.2 |
CVLA1-2 | CDLF1-2 | 0.37 | H (m) |
12 | 11.8 | 11.5 | 11.2 | 11 | 10.5 | 9.8 | 9.2 | 8.5 | 7.8 |
CVLA1-3 | CDLF1-3 | 0.37 | 17.5 | 17 | 16.8 | 16.5 | 16 | 15.5 | 14 | 13.5 | 12 | 10.5 | |
CVLA1-4 | CDLF1-4 | 0.37 | 23.5 | 23 | 22.5 | 22 | 21 | 20.5 | 18.5 | 18 | 16.5 | 14 | |
CVLA1-5 | CDLF1-5 | 0.37 | 29 | 28.5 | 28 | 27.5 | 26.5 | 26 | 24 | 23 | 20.5 | 17.5 | |
CVLA1-6 | CDLF1-6 | 0.37 | 35 | 34.5 | 34 | 33 | 32 | 31 | 28 | 27 | 25 | 22 | |
CVLA1-7 | CDLF1-7 | 0.37 | 41 | 40 | 39 | 38.5 | 37 | 35 | 33 | 32 | 29 | 25 | |
CVLA1-8 | CDLF1-8 | 0.55 | 46.5 | 46 | 45.5 | 44 | 42 | 40 | 38 | 36 | 33 | 29 | |
CVLA1-9 | CDLF1-9 | 0.55 | 52 | 51.5 | 51 | 49.5 | 47.5 | 46 | 44 | 41 | 37 | 34 | |
CVLA1-10 | CDLF1-10 | 0.55 | 58 | 57.5 | 57 | 56 | 54 | 52 | 48 | 46 | 41.5 | 37 | |
CVLA1-11 | CDLF1-11 | 0.55 | 65 | 63 | 62.5 | 61 | 59 | 56 | 54 | 50 | 46 | 40 | |
CVLA1-12 | CDLF1-12 | 0.75 | 70 | 69 | 68 | 66 | 64 | 62 | 58 | 55 | 49 | 43 | |
CVLA1-13 | CDLF1-13 | 0.75 | 75 | 74.5 | 74 | 71 | 69 | 66 | 63 | 59 | 54 | 47 | |
CVLA1-15 | CDLF1-15 | 0.75 | 87 | 86 | 85 | 84 | 80.5 | 77 | 72 | 68 | 62 | 53 | |
CVLA1-17 | CDLF1-17 | 1.1 | 99 | 97.5 | 97 | 95 | 9 | 87 | 81.5 | 70 | 69 | 59 | |
CVLA1-19 | CDLF1-19 | 1.1 | 110.5 | 109 | 108 | 106 | 101 | 97 | 91 | 86 | 78 | 66 | |
CVLA1-21 | CDLF1-21 | 1.1 | 122 | 120.5 | 119.5 | 116 | 112 | 108 | 101 | 95 | 86 | 73 | |
CVLA1-23 | CDLF1-23 | 1.1 | 135 | 132.5 | 130 | 126 | 122 | 117 | 111 | 104 | 94 | 80 | |
CVLA1-25 | CDLF1-25 | 1.5 | 147 | 144 | 141 | 138 | 133 | 128 | 121 | 114 | 103 | 87 | |
CVLA1-27 | CDLF1-27 | 1.5 | 158 | 156 | 154 | 150 | 144 | 138 | 130 | 121 | 112 | 96 | |
CVLA1-29 | CDLF1-30 | 1.5 | 175 | 173 | 171 | 166 | 160 | 154 | 145 | 136 | 124 | 108 | |
CVLA1-33 | CDLF1-33 | 2.2 | 193 | 191 | 188 | 183 | 176 | 170 | 160 | 150 | 136 | 120 | |
CVLA1-36 | CDLF1-36 | 2.2 | 212 | 209 | 205 | 200 | 192 | 184 | 174 | 164 | 150 | 133 |
This is generally the effectiveness of the water pump. Flow rate refers to the time taken by a water pump to pump a specific amount of water mostly measured in liters per minute. If you are going to use the water pump for either job sites or farms, you should purchase one that has the ability to pump over 2500 liters of water per minute. On the other hand, a pump with a flow rate of between 100 – 200 liters per minute is suitable for any home use.
Most pumps have an inlet size of between 1 to 6 inches but in some cases, it can be more. Centrifugal water pumps also operate in a similar way i.e. sucking in water from the inlet and discharging it through the outlet valve. In that case, the bigger the size of an inlet valve, the more amount of water the pump will be able to pump out and the faster it will do the job.
The maximum head of a water pump refers to the longest distance in terms of height that the pump will be able to pump water. For instance, if you buy a water pump with a maximum head of 60 meters, if you try to pump water to levels higher than that then the flow rate will be zero. Generally, the type of pump you choose should have a maximum head higher than the height you intend to pump the water.
The first thing to consider is the brand of the water pump. The engine or the motor can also tell you the quality of the pump. Conduct the necessary research and surveys on how the quality of a water pump should be.
The type of water you are going to pump is also a factor to consider. Transfer pumps are different from firefighting pumps. Other types of pumps include chemical pumps and trash pumps.
After purchasing all kinds of pumps, it is easy to damage the pumps if the knowledge about how to use the pumps is insufficient. Therefore, it is necessary to understand and master the knowledge of how to use the pumps correctly.
When using the water pump, after connecting the power supply, carefully observe the operation of the water pump. The water outlet should be continuous and uniform, and the water pump can be used only when there is no vibration and noise. In case of a sudden shutdown during operation, immediately disconnect the power supply and check the cause. The interval between the two starts of the pump shall be limited to the return of all the water in the pump. If it is started too early, the motor will be burned due to excessive resistance and a water hammer in the water pipe. In addition, if the water pump is installed in the well, it should be noted that the flow of the water pump should conform to the normal water output of the well, otherwise it will cause the empty machine to run and burn the motor.
① In the production of chemical and petroleum sectors, most of the raw materials, semi-finished products and finished products are liquids, and the production of semi-finished and finished raw materials into semi-finished products and finished products needs to go through complex technological processes. During these processes, pumps play a role in transporting liquids and providing pressure flow for chemical reactions. In addition, in many installations, pumps are used to adjust the temperature.
② In agricultural production, pumps are the main irrigation and drainage machinery. my country's rural areas are vast, and a large number of pumps are needed in rural areas every year. Generally speaking, agricultural pumps account for more than half of the total output of pumps.Pumps are also the most used equipment in the mining and metallurgical industries. The mine needs to be drained by pumps, and in the process of beneficiation, smelting and rolling, pumps are needed to supply water.
③ In the power sector, nuclear power plants need nuclear main pumps, secondary pumps, and tertiary pumps, and thermal power plants need a large number of boiler feed pumps, condensate pumps, oil and gas mixing pumps, circulating pumps, and ash pumps.
④ In national defense construction, the adjustment of aircraft flaps, tail rudders and landing gear, the rotation of warships and tank turrets, and the ups and downs of submarines all require pumps. High pressure and radioactive liquid, and some also require the pump without any leakage.
⑤ In short, whether it is aircraft, rockets, tanks, submarines, drilling, mining, trains, ships, or everyday life, pumps are needed everywhere, and pumps are running everywhere. That's why the pump is listed as a general-purpose machine, which is a major product in the machinery industry.
⑥ Electric pumps, i.e. pumps driven by electricity. The electric pump is composed of a pump body, a water lift pipe, a pump base, a submersible motor (including cables) and a starting protection de